8.3.8
8.3.9
Turn pointer clockwise to surrounding
temperature mark on gauge while continu-
ing to pump lever slowly.
If unit is over-filled, oil will leak out small
bleeder holes in master control. If so, re-op-
en valve (C), continuing to pump unit, and
reset temperature pointer. Then close valve
(C).
8.3.10 Open valve (D) five turns.
8.3.11 Cap filler hose (E).
8.3.12 The relationship of the control lever to the
regulating cylinder on the fuel pump is now
set by first making sure regulating cylinder
is in off positon.
8.3.13 Piston is still in raised position from 8.2.1,
so the fuel pump lever may be activated to
have fuel pressure move regulating cylinder
to off position.
8.3.14 Move master control lever to off position
and then close valves (A) and (B).
8.3.15 The relationship of the master lever to the
pump regulating cylinder may be fine tuned
by opening valve (A) and adjusting lever,
then re-closing.
83.16 If sponginess is evident in system, it indi-
cates air still exists in the lines. Repeat
bleeding procedure.
Figure 20
11