TM 5-3895-363-13&P
APPENDIX G
LUBRICATION INTERVALS
Hard time intervals and the related man-hour
times are based on normal operation. The man-
hour time specified is the time you need to do all
the services prescribed for a particular interval.
Change the hard time interval if your lubricants
are contaminated or if you are operating the
equipment under adverse operating conditions,
including longer than-usual operating hours.
The hard time interval may be extended during
periods of low activity. If extended, adequate
preservation precautions must be taken.
WARNING
Dry cleaning fluid is flammable. Do not
use near flame or excessive heat. Use only
with adequate ventilation. Avoid
prolonged breathing of vapors and
minimize skin contact.
Clean parts or fittings with dry cleaning solvent
(SD). Type II or equivalent. Dry before lubricating.
Dotted arrow shafts indicate lubrication on both
sides of equipment. A dotted circle indicates a
drain below. Relubricate all items found con-
taminated after fording or washing.
The lowest level of maintenance authorized to
lubricate a point is indicated by one of the fol-
lowing symbols as appropriate: Operator/Crew
(C); and Organizational Maintenance (O).
LUBRICANTS. The following is a list of
lubricants with military symbols and applicable
specification numbers.
OE/HDO
GAA
OEA
TRC MOLY
MIL-L-2104
MIL-G-10924
MIL-L-46167
HIGH TEMP GREASE
(MANUFACTURED BY
TEXAS REFINERY CORP)
* The time specified is the time required to perform all services
at the particular Interval.
* TOTAL MAN- HOURS
* TOTAL MAN-HOURS
INTERVAL
30-40 Min of Operation
2 Hours of Driving Time
(note 1)
MAN-HOURS
0.3
0.5
INTERVAL
MAN-HOURS
0.2
As needed
G-1